ID-72 Ilford PQ Developer -
for X-ray films and papers
| Phenidone |
0.22 g |
|
| Sodium Sulphite (anh) |
72 g |
|
| Hydroquinone |
8.8 g |
|
| Sodium Carbonate (anh) |
48 g |
|
| Potassium Bromide |
4 g |
|
| Benzotriazole 1% |
10 ml |
|
| Water to |
1 litre |
|
To use: Aerial Films - use Full
Strength, development times approx 5 mins @ 20°C
ID-19 is the MQ version of this
developer
ID-72 Replenisher
| Phenidone |
0.25 g |
|
| Sodium Sulphite (anh) |
72 g |
|
| Hydroquinone |
12.5 g |
|
| Sodium Carbonate (anh) |
48 g |
|
| Sodium Hydroxide |
7.5 g |
|
| Benzotriazole 1% |
8 ml |
|
| Water to |
1 litre |
|
|